File
5
SYSTEM MESSAGESMAINTENANCE
Ed. 04 5/24Réf. 3EH 21000 BSAA
58 ISDN BOARD FAULT
A level 1 error was detected
by the board's OBC
Board lo-
cation.
Access
marker
INFO 0 =type of error (not significant)
72 UNSUCCESSFUL ATTEMPT
TO PRINT
Message emitted by the for-
matter (printer) after every 5
failed print attempts.
Check the
printer
and its
connec-
tion ca-
ble.
103 OBC FAULT Board lo-
cation.
INFO 0 and 1 = type of fault
200 4070 IO/EO BASE: SLAVE
LINK CONNECTED TO IN-
VALID INTERFACE
Board lo-
cation.
Interface
marker
INFO 0 = interface number invalid
INFO 1 = base station operating sta-
tus
Check the
cables on
the 2nd
link in the
base sta-
tion
201 4070 IO/EO
BASE: FREQUENCY REJEC-
TION
Discrepancy between the
number of frequencies con-
figured by the installer and
the number of DECT fre-
quencies processed
Board lo-
cation.
Interface
marker
INFO 0 to 3 = bitmap of frequencies
authorized and in use
202 4070 IO/EO BASE: LOSS
OF SYNCHRONIZATION
ON UA LINK 0
Board lo-
cation.
Interface
marker
INFO 0 = link status (0 = link KO; 1
= link OK)
203 4070 IO/EO BASE: LOSS
OF SYNCHRONIZATION
ON UA LINK 1
Board lo-
cation.
Interface
marker
INFO 0 = link status (0 = link KO; 1
= link OK)
204 4070 IO/EO BASE: NO RE-
PLY ON DSP PRESENT (RE-
SET)
Board lo-
cation.
Interface
marker
TYPE MESSAGE LOCA-
TION
ADDITIONAL INFORMATION ACTION

Table of Contents

Other manuals for Alcatel OmniPCX Office

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel OmniPCX Office and is the answer not in the manual?

Alcatel OmniPCX Office Specifications

General IconGeneral
VoIP SupportYes
SIP SupportYes
ISDN SupportYes
Analog SupportYes
Integrated Voice MailYes
Auto AttendantYes
ConferencingYes
VoIP ProtocolsSIP, H.323
Power Supply100-240 VAC, 50/60 Hz
Network Interfaces10/100 Mbps Ethernet
Humidity10% to 90% non-condensing