File
5
SYSTEM MESSAGESMAINTENANCE
Ed. 04 23/24Réf. 3EH 21000 BSAA
Additional information contained in message 112 (INFO 1: type of error)
01H: transmission fault (Reflexes sets)
03H: set not responding or response incorrect
04H: set no longer responding
05H: message flow too large for set (Reflexes sets)
07H: transmission fault (Reflexes sets)
08H: transmission fault (Reflexes sets)
09H: transmission fault (Reflexes sets)
10H: no more memory available to store the messages intended for the subscriber (Reflexes sets)
TYPES OF INTERFACE (INFO 0 of message 113)
01H: analog set interface
03H: T0 access interface
04H: T2 access interface
05H: S0 set interface
14H: Reflexes set interface
20H: master DECT base interface
21H: slave DECT base interface
22H: DECT Reflexes interface
25H: Multi-Reflexes interface
26H: IP interface
27H: IP network interface
2AH to 2DH: interfaces MSG1 to MSG4
2FH: Audio In interface
30H: Audio Out interface
31H: General bell interface
35H to 38H: interfaces MSG5 to MSG8
1DH: analog modem interface on RAXX board
1EH: ECMA 102 modem interface on RAXX board