Rockwell Automation Publication 2198-UM001I-EN-P - May 2019 191
Kinetix 5500 Safe Torque-off - Integrated Safety Chapter 10
Functional Safety Considerations
ATTENTION: Before maintenance work can be performed in Program mode,
the developer of the application must consider the implications of allowing
motion through motion direct commands and should consider developing
logic for run-time maintenance operations to meet the requirements of
machine safety operating procedures.
ATTENTION: Motion is allowed when motion direct commands are used in
Program mode and STO function is not available.
Motion direct commands issued when the controller is in Program mode
causes the drive to bypass the STO Active condition.
It is your responsibility to implement additional preventive measures to
maintain safety integrity of the machinery during execution of motion direct
commands in Program mode.
ATTENTION: To avoid personal injury and damage to equipment in the event
of unauthorized access or unexpected motion during authorized access,
return the controller to RUN mode and remove the key before leaving the
machine unattended.

Table of Contents

Other manuals for Allen-Bradley Kinetix 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley Kinetix 5500 and is the answer not in the manual?

Allen-Bradley Kinetix 5500 Specifications

General IconGeneral
BrandAllen-Bradley
ModelKinetix 5500
CategoryServo Drives
LanguageEnglish

Related product manuals