Rockwell Automation Publication 2198-UM001I-EN-P - May 2019 221
Size Multi-axis Shared-bus Configurations Appendix C
Shared AC/DC Hybrid Configurations
In shared AC/DC hybrid configurations, three-phase AC input power is
supplied to two or more (leader) drives that act as converters. This parallel
converter configuration increases the DC power supplied to the inverter
(follower) drives:
The leftmost drives in a hybrid configuration act as parallel converter
drives and must be of the same power rating (catalog number).
Shared DC (inverter) drives mounted to the right of the shared AC/DC
(converter) drives must have the same or lower power rating (catalog
number) than the shared AC/DC drives.
The total motoring load must not exceed the rated load for the drives
sourcing the DC power. Each follower drive must be sized for the motor
load connected to it.
Total available converter power is derated by 30%.
The maximum number of drives configured in the project file as
Shared AC/DC is restricted according to Table 80 on page 220
.
The maximum number of drives configured in the project file as
Shared DC is restricted according to Table 79 on page 219
.
Shared AC/DC hybrid configurations support Bulletin 2198 capacitor
modules.
Figure 109 - Typical Shared AC/DC Hybrid Configuration
(1) For Bulletin 2198 capacitor module maximum values, refer to the Kinetix 5500 Capacitor Module Installation Instructions,
publication 2198-IN004
.
For an example shared AC/DC hybrid installation with additional details,
refer to Typical Shared AC/DC Bus Hybrid Installations
on page 21.
Bonded Cabinet
Ground
Three-phase
Input Power
24V Input
Control Power
2198-H040-ERSx
Common-bus (converter)
Leader Drives
2198-H008-ERSx
Common-bus (inverter)
Follower Drives
2198-CAPMOD-1300 Capacitor Module
(1)
(optional component)
DC Bus Connections