76 Rockwell Automation Publication 2198-UM001I-EN-P - May 2019
Chapter 5 Connect the Kinetix 5500 Drive System
Figure 38 - Impedance-grounded Power Configuration (WYE Secondary)
(1) The AC ground jumper is removed and the DC ground jumper is removed. See Figure 42 on page 79 for access to ground screws.
Figure 39 - Corner-grounded Power Configuration (Delta Secondary)
(1) The AC ground jumper is removed and the DC ground jumper is removed. See Figure 42 on page 79 for access to ground screws.
Refer to Power Wiring Examples beginning on page 194 for input power
interconnect diagrams.
L3
L2
L1
1
2
L3
L2
L1
1
2
Transformer
Three-phase
Input VAC
Phase Ground
Transformer (WYE) Secondary
Bonded Cabinet Ground
Ground Grid or
Power Distribution Ground
Kinetix 5500 Servo Drive
(top view)
Circuit
Protection
Connect to
Ground Stud
AC Screw
(1)
DC Screw
L3
L1
L2
1
2
L3
L2
L1
1
2
Transformer (Delta) Secondary
Bonded Cabinet Ground
Transformer
Ground Grid or
Power Distribution Ground
Kinetix 5500 Servo Drive
(top view)
Circuit
Protection
Connect to
Ground Stud
AC Screw
(1)
DC Screw