Appendix A Specifications
A-20
Table A.3.4-4 Histogram
Item Specifications
Histogram
Setting functions related to the Histogram measurement
Target Channel
ON, OFF Measures the Active Channel
Axis
Amplitude, Time
Marker
X1, X2, Y1, Y2
Result Display
Mean, Std. Dev, p-p, Hits
Table A.3.4-5 Mask Test
Item Specifications
Mask Test
Setting functions related to the Mask Test measurement
Target Channel
Turns on and off by channel.
Compliance Mask
Selects the Mask to be used for measurement from files.
Mask Margin Test
Method
One Shot
Continuous
Align Method
Function to specify the method to set Mask position.
Auto Align Zero/One/Crossing
User Defined
Alignment Marker
X1,
X, Y1,
Y
Alignment Marker
Display On/ Display Off
Mask Margin
100 to +100%
Margin Type
Selects from Hit Count or Hit Ratio.
Hit Count
1 to 999999999*
1
Hit Ratio
1E12 to 9E–01*
2
Mask Area
Restriction
ON/OFF
Function to limit Mask effective area in Mask measurement
Angle
90 to 90º (1º step)
Width
0.01 to 1 UI (0.01 step)
Result Display
Total Samples, Total Waveforms, Mask Margin [%], Hit Count,
Total Failed Samples, Top Mask Failed Samples,
Center Mask Failed Samples, Bottom Mask Failed Samples
*1: Fail Sample upper limit value for Margin measurement
*2: Hit Count is automatically set with the total sample and set
probability.