System Products 155
© 2020, ATEÏS. All rights reserved.
Mode
Definition
Status
Monitoring
NO
Short Circuit
Open: Inactive
Close: Active
Line Open
Monitoring
NC
Short Circuit
Open: Active
Close: Inactive
Line Open
Non-Monitoring
NO
Open: Inactive
Close: Active
Non-Monitoring
NC
Open: Active
Close: Inactive
Do not input the external power voltage to this connector, it might damage the device.
3.2.6.3 Configuration
The configuration of URGP 32I can be done by using the URGP 32I component on Ateis Studio. See
URGP 32I Component chapter for details.