IDA8 Global-Net User Manual180
© 2020, ATEÏS. All rights reserved.
3.3.7.4 PDC
Full & Partial Redundancy
From IDA8 to RU-MAIN:
o IDA8: PDC1~4.
o RU-MAIN: P_PDC1, S_PDC1.
From RU-MAIN to PPM-IT5/PSS-AS etc.
o RU-MAIN: PDC1.
3.3.7.5 Normal/Backup Amplifier Input
3.3.7.5.1 Matrix Mode
Full & Partial Redundancy
Normal AMP input from IDA8C to RU-MAIN:
o IDA8C: AMP Inputs Zone1~8.
o RU-MAIN: AMP Inputs For Zone1~8 (P_ZONE, S_ZONE).