7.1.14 Remote Offline
The IDA8C/S cannot communicate with peripheral devices.
Indication:
LED Indicator: When this error is detected, the following LEDs will light up:
o G. Fault LED on the front panel of the IDA8C/S.
Log:
o The text messages display at the touch screen of the IDA8C as below.
"Remote Offline"
"PPM Port:2 ID:1", where Port N is the Nth PDC port for the peripheral connection,
the ID is the unique number for each peripheral device on the PDC port.
o A text message displays at the window [Machine Fault Record] in Ateis Studio, see the
picture as below.
A buzzing sound will be outputted to the monitoring speaker on the front panel of the IDA8C.
Troubleshooting:
Replace the peripheral device with a working one. If the fault is resolved, the problem is from
the peripheral device. Send the peripheral device to your technician.
If the fault is not resolved, change the IDA8C/S and contact your technician.