EasyManuals Logo

Ateis IDA8C User Manual

Default Icon
535 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #182 background imageLoading...
Page #182 background image
IDA8 Global-Net User Manual182
© 2020, ATEÏS. All rights reserved.
3.3.7.6 Normal/Backup Amplifier Output
3.3.7.6.1 Matrix Mode
Full & Partial Redundancy
Normal AMP Output from IDA8C to RU-MAIN:
o IDA8C: Zone1~8 AMP O.
o RU-MAIN: Zone1~8 (P_AMPO, S_AMP O).
Normal AMP Output from RU-MAIN to SPA:
o RU-MAIN: Zone1~8 (AMP O)
o SPA: Audio Output.
Backup AMP Output from IDA8C to RU-MAIN:
o IDA8C: Backup AMP1 (AMP O).
o RU-MAIN: Backup AMP1 (P_AMPO, S_AMP O).
Backup AMP Output from RU-MAIN to SPA.
o RU-MAIN: Backup AMP1 (AMP O).
o SPA: Audio Output.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ateis IDA8C and is the answer not in the manual?

Ateis IDA8C Specifications

General IconGeneral
BrandAteis
ModelIDA8C
CategorySecurity System
LanguageEnglish

Related product manuals