2. There will be a window which displays the
event information corresponded to the
state and value.
2. Click [Content...] button on Event Manager window to open the settings window of event.
State: Click [State] page tab to switch the state of value trigger event.
Element: The element of the component controlled by value trigger.
Component: The component of device contains the previously element.
Device/System: The device/system contains the previously component.
Value: The value that binds with the state. When a Value Trigger Event has been triggered, the
source that triggers the event will send a state number to the system and the event will map this
state number to a value and then sets it to the element.
Remove: Remove the element controlled by the event.
This action only removes the relation between the element and event and does not delete the
element.
Clear: Remove all elements controlled by the event.
5.3.3 Value Control
This event is used for controlling the element value for triggering the event.
Click [Add] to create a new event, and a pop-up setting
window will be displayed, here you can choose which
kinds of event users acquired. Select [Value Control]
option on [Type] drop-down box, then press [OK].
Event Settings