IDA8 Global-Net User Manual492
© 2020, ATEÏS. All rights reserved.
IP Attack:xx.xx.xx.xx
(xx = ip address)
There is some network client attack the machine. IDA8
will block its communication.
Global AteisNet PA/B Shutdown
Global ATEIS net card detect unknown communication
so that the port disable, you need restart machine to
recovery it.
Local AteisNet PA/B Shutdown
Local ATEIS net card detect unknown communication
so that the port disable, you need restart machine to
recovery it.
Local AteisNet Protect Enable/Disable
Local ATEIS net card detect unknown communication
so that enable protection function.
Global AteisNet PA/B Unstable
Global ATEIS net port has unstable communication, it
may cause by its fiber cable or network card problem.
Local AteisNet PA/B Unstable
Local ATEIS net port has unstable communication, it
may cause by its fiber cable or network card problem.
Global AteisNet Protect Enable/Disable
Global ATEIS net card detect unknown communication
so that enable protection function.
Some command process too long so that machine
auto restart, please catch the logs and send to Taiwan
engineer.
EVAC CH:xx yy, zz
(xx = channel number, yy=open/short/on/off,
zz=monitoring value)
Evacuation input detail status
Fan:xx xx xx xx xx xx
(xx = fan deteil measure value)
Fan fail detail measure value
Global netcard restart because some static electricity
GNT Port xx yy Error
(xx=port, yy=CRC or PHY)
Global netcard port has some hardware error
LNT Port xx yy Error
(xx=port, yy=CRC or PHY)
Local netcard port has some hardware error
SIP Registration Success/Failure
SIP Server connection status
Dial xxx
Call from xxx
Call Start
Call End
(xxx = telephone number)