EasyManua.ls Logo

Azbil MagneW FLEX+/PLUS+ MGG10C - Normal Direction, External Switching Dual Range

Azbil MagneW FLEX+/PLUS+ MGG10C
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Using the display panel Azbil Corporation
4-32 Model MGG10C/14C - MagneW FLEX+/PLUS+ Converter
Normal direction, external switching dual range
The range is switched via an external switching command to the contact input.
Also, the wide/narrow range distinction contact output (status signal) can be sent out
using the same timing.
Analog output
j When AUTO is selected for an analog output
Range No.1 4 to 20 mA DC
Range No.2 4 to 20 mA DC
k When WIDE is selected for an analog output
4 to 20 mA DC is output according to either range No.1 or range No.2 whichever
has the wider range.
When there is a pulse output
The pulse weight is the same for both ranges No.1 and No.2.
Contact input
Range switching command contact input
Range No.1: Close
Range No.2: Open
Contact output (select functions as required.)
Range switching distinction status signal
The contact output status at shipment is as follows.
Range No.1: Closed
Range No.2: Open
Reverse setting is also possible.

Table of Contents

Related product manuals