Azbil Corporation Using the display panel
Model MGG10C/14C - MagneW FLEX+/PLUS+ Converter 4-45
Specic gravity
This function is used to set the specic gravity when selecting a weight unit (t, kg, g,
lb) in the ow rate measurement range setting.
Step
Screen
Procedure
(English) (Japanese)
1
GRAVITY
1.0000
1.0000
Enter ENGINEERING MODE
(see page 4-23).
Use the
or key to cycle
through the screens until the
GRAVITY screen appears.
2
GRAVITY
1.0000
1.0000
Touch the key until the
cursor is at the value to be
changed.
Default setting: 1.0000
Setting range: 0.1000 to 9.9999
3
GRAVITY
1.0050
1.0050
Touch the or key to
change the value.
4
GRAVITY
1.0050
1.0050
Touch the key until the
cursor is back at the mode
indicator.