Azbil Corporation  Using the display panel
Model MGG10C/14C - MagneW FLEX+/PLUS+ Converter  4-45
Specic gravity
This function is used to set the specic gravity when selecting a weight unit (t, kg, g, 
lb) in the ow rate measurement range setting.
Step
Screen
Procedure
(English) (Japanese)
1
GRAVITY
Enter ENGINEERING MODE 
(see page 4-23). 
Use the 
 or   key to cycle 
through the screens until the 
GRAVITY screen appears.
2
GRAVITY
Touch the   key until the 
cursor is at the value to be 
changed.
Default setting: 1.0000
Setting range: 0.1000 to 9.9999
3
GRAVITY
       1.0050
Touch the   or   key to 
change the value.
4
GRAVITY
       1.0050
              1.0050
Touch the   key until the 
cursor is back at the mode 
indicator.