4. Physical installation projector
Necessary parts
• (for 3W +N+P E, 230/400V) Certified power cable, m inimum 4 mm² or AWG 10, 500V r ated, cable diameter between 11 mm and
21 mm or
• (for 3W +P E, 208V) Certified power cable, m inimum 4 m m² or AWG 10, 300V rated, c able diameter between 11 mm and 21 mm
• Circuit breaker maximum 40A
How to connect
1. Remove the back cover.
2. Remove the power input c over.
3. L oosen the cable gland fixation ring (1).
Note: The c able gland ( 1) is specified for cables with a diameter between 11mm and 21m m.
1
Image 4-12
Power cable connection
4. P ush the s tripped power supply cable through the cable gland. When us ing a flexible power cord, ma ke sure that each conductor
end is provided with a n end sleeve.
Fix the cable in the cable gland by securing ring 1 w ith an adjustable wrench.
5. Connect the power cord with the terminal barrier strip. Use a flat torque screw driver set to 1.4 Nm.
Always con nect the ground wire (PE) with the connector indicated with PE on the terminal barrier s trip.
If a neutral conductor is available, connect always to the connector indicated with N on the terminal b arrier strip
Warning: Always connect first the PE wire .
3W+N+PE
3W + PE
L1
L2
L3
N
PE
L1
L2
L3
PE
Image 4-13
Terminal connections
6. Reinstall the power connection cover.
R5906753 DPXK BLP SERIES 20/11/2017
33