EasyManua.ls Logo

Barco DP2K-36BLP - How to Connect

Barco DP2K-36BLP
185 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4. Physical installation projector
Necessary parts
(for 3W +N+P E, 230/400V) Certied power cable, m inimum 4 mm² or AWG 10, 500V r ated, cable diameter between 11 mm and
21 mm or
(for 3W +P E, 208V) Certied power cable, m inimum 4 m or AWG 10, 300V rated, c able diameter between 11 mm and 21 mm
Circuit breaker maximum 40A
How to connect
1. Remove the back cover.
2. Remove the power input c over.
3. L oosen the cable gland xation ring (1).
Note: The c able gland ( 1) is specied for cables with a diameter between 11mm and 21m m.
1
Image 4-12
Power cable connection
4. P ush the s tripped power supply cable through the cable gland. When us ing a exible power cord, ma ke sure that each conductor
end is provided with a n end sleeve.
Fix the cable in the cable gland by securing ring 1 w ith an adjustable wrench.
5. Connect the power cord with the terminal barrier strip. Use a at torque screw driver set to 1.4 Nm.
Always con nect the ground wire (PE) with the connector indicated with PE on the terminal barrier s trip.
If a neutral conductor is available, connect always to the connector indicated with N on the terminal b arrier strip
Warning: Always connect rst the PE wire .
3W+N+PE
3W + PE
L1
L2
L3
N
PE
L1
L2
L3
PE
Image 4-13
Terminal connections
6. Reinstall the power connection cover.
R5906753 DPXK BLP SERIES 20/11/2017
33