EasyManua.ls Logo

Calrec Apollo - Apollo Sample Rate Comparison

Calrec Apollo
214 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CALREC Putting Sound in the Picture 13
SIGNAL PROCESSING AT 48KHZ AND 96KHZ
Apollo Sample Rate @ 48kHz Sample Rate @ 96kHz
Input Channels
1020 510
Main Output Buses
and LtRt outputs
Up to 16 from Main/Group
pool of 128 mono legs
16 LtRt outputs
Up to 8 from Main/Group
pool of 64 mono legs
Up to 8 LtRt outputs
Audio Group Buses
Up to 48 from Main/Group
pool of 128 mono legs
Up to 24 from Main/Group
pool of 64 mono legs
Track Output Buses
96 48
Aux Output Buses
Up to 48 mono / stereo from
pool of 48 mono legs
Up to 24 mono / stereo from
pool of 24 mono legs
Direct / Mix-Minus Outputs
Up to 4 sends per path from
pool of 512 mono legs
Up to 4 sends per path from
pool of 256 mono legs
Insert Send & Returns
Pool of 256 mono legs Pool of 128 mono legs
Input Delay
Up to 2.73s per input from pool
of 256 mono legs
Up to 2.73s per input from pool
of 128 mono legs
Output Delay
Up to 2.73s per output from
pool of 256 mono legs
Up to 2.73s per input from pool
of 128 mono legs
EQ
6 full bands of parametric EQ
on each channel, group & main
path
6 full bands of parametric EQ
on each channel, group & main
path
Dynamics
2 x compressor / limiter & 1
x expander / gate on each
channel, group & main path
2 x compressor / limiter & 1
x expander / gate on each
channel, group & main path
ROUTER
Apollo Sample Rate @ 48kHz Sample Rate @ 96kHz
Integral Router
8192x8192
4096x4096 (minimum)
1 x 96 kHz route = 2 x 48 kHz
routes
Hydra2 ports
16 / 32 16/32
Audio Channels per Port
Up to 512 Up to 256
APOLLO SAMPLE RATE COMPARISON

Table of Contents

Other manuals for Calrec Apollo

Related product manuals