4-60 Model D9854 Advanced Program Receiver Installation and Operation Guide 4021470 Rev D
Setup Menu: CI, Continued
Stream
Description: Set the stream category if the PID value is unknown.
Set to User if you want to manually enter a stream code for the
stream type.
Parameters: Aud (audio), Vid (video), Subtitle (subt), TTX, User.
Type
Description If you selected User in the Stream parameter, you can manually
enter the stream type value.
Parameters: 0 to 255 bytes.
Inst
Description: Set the instance of the selected stream.
Parameters: 1 to 64.
Query
Description: Set to Enable to query the CAM prior to decryption to ensure that
the program can be decrypted.
Parameters: Enabled or Disabled (default).
Auto Reset
Description: Set to Enable to automatically reset the card.
Parameters: Enable or Disabled (default).
List Mgmt
Description: Set to AddDel (default) to add or delete programs individually in
the CAM.
Set to Update All to automatically update and reset all the
programs each time you add or modify the programs available via
the CAM.
Parameters: AddDel or Update All.
TS_ON_ID
Description: Set to Enable if you want to restrict the incoming transport stream.
If the incoming stream does not match the transport stream and
original network ID specified (TS_ID and ON_ID), the program will
not be decrypted.
Parameters: Enable or Disable (default).
TS_ID
Description: Specify the Transport ID.
Parameters: 0 to 65535