4021470 Rev D D9854 Advanced Program Receiver Installation and Operation Guide 4-23
Status Menu: TS Input, Continued
PROGRAM STATUS
PE
Description: Indicates the Program Entry number.
Parameters: PE1 to PE16.
SR Status
Description: This displays the status of an alternate authorized program/service
from the same transport stream when the receiver is not authorized
to view the primary program.This is an uplink initiated function
that maps the alternate service to the original (primary) service
PIDs, replacing the original service with the alternate service at the
digital transport output. No local intervention is required by the
receiver operator for provision of this service replacement feature.
Parameters: Not Started - Indicates that an event has not started.
Primary - Indicates that a service replacement event is active, but
the primary program is being displayed.
Alternate - Indicates that a service replacement event is active, and
that the receiver has tuned to and is displaying the alternate
program/event as it is not authorized to view the scheduled event.
SR Event Type
Description: Indicates the type of service replacement event.
Parameters: None - Indicates that no service replacement event is scheduled.
Scheduled - Indicates that all receivers will tune to the alternate
program at the scheduled time. This setting is only applicable to
current PE1 (i.e., PowerVu) programs; not PE2 through PE16.
CA - Indicates that only receivers unauthorized to view the
scheduled program will tune to the alternate program according to
the selected authorization tier bits. This setting is only applicable to
current PE1 (i.e., PowerVu) programs; not PE2 through PE16.
Cue Trigger - Indicates that only receivers authorized by the Cue
Trigger mask will tune to the scheduled program/event. Cue
triggers can only be initiated /controlled on PE1 (i.e., PowerVu).

Table of Contents

Other manuals for Cisco D9854

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco D9854 and is the answer not in the manual?

Cisco D9854 Specifications

General IconGeneral
ModelD9854
CategoryReceiver
OutputASI, IP
DecodingMPEG-2
Conditional AccessBISS
Receiver TypeProfessional IRD
解密DVB-CSA, BISS, AES
Input Frequency Range950 MHz to 2150 MHz
Modulation FormatsQPSK, 8PSK
Symbol Rate1 to 45 Msps
Power Supply100-240 VAC, 50/60 Hz
Power Consumption40W (typical)
Operating Temperature0°C