2-158
Cisco IE 3000 Switch Command Reference
OL-13019-01
Chapter 2 IE 3000 Switch Cisco IOS Commands
ip igmp snooping querier
Usage Guidelines Use this command to enable IGMP snooping to detect the IGMP version and IP address of a device that
sends IGMP query messages, which is also called a querier.
By default, the IGMP snooping querier is configured to detect devices that use IGMP Vers io n 2
(IGMPv2) but does not detect clients that are using IGMP Ver si on 1 (IGMPv1). You can manually
configure the max-response-time value when devices use IGMPv2. You cannot configure the
max-response-time when devices use IGMPv1. (The value cannot be configured and is set to zero).
Non-RFC compliant devices running IGMPv1 might reject IGMP general query messages that have a
non-zero value as the max-response-time value. If you want the devices to accept the IGMP general query
messages, configure the IGMP snooping querier to run IGMPv1.
VLAN IDs 1002 to 1005 are reserved for Token Ring and FDDI VLANs and cannot be used in IGMP
snooping.
Examples This example shows how to globally enable the IGMP snooping querier feature:
Switch(config)# ip igmp snooping querier
This example shows how to set the IGMP snooping querier maximum response time to 25 seconds:
Switch(config)# ip igmp snooping querier max-response-time 25
This example shows how to set the IGMP snooping querier interval time to 60 seconds:
Switch(config)# ip igmp snooping querier query-interval 60
This example shows how to set the IGMP snooping querier TCN query count to 25:
Switch(config)# ip igmp snooping querier tcn count 25
This example shows how to set the IGMP snooping querier timeout to 60 seconds:
Switch(config)# ip igmp snooping querier timeout expiry 60
This example shows how to set the IGMP snooping querier feature to version 2:
Switch(config)# ip igmp snooping querier version 2
You can verify your settings by entering the show ip igmp snooping privileged EXEC command.
Related Commands Command Description
ip igmp snooping report-suppression Enables IGMP report suppression.
show ip igmp snooping Displays the IGMP snooping configuration.
show ip igmp snooping groups Displays IGMP snooping multicast information.
show ip igmp snooping mrouter Displays the IGMP snooping router ports.

Table of Contents

Other manuals for Cisco IE-3000-8TC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco IE-3000-8TC and is the answer not in the manual?

Cisco IE-3000-8TC Specifications

General IconGeneral
Switching Capacity16 Gbps
MAC Address Table Size8000
Uplink Ports2 x 10/100/1000Base-T or SFP (Small Form-Factor Pluggable)
Operating Temperature-40°C to 70°C
MountingDIN rail
Ports8 x Ethernet 10/100Base-TX ports
Jumbo Frame SupportYes