Page #381 background image
2-355
Cisco IE 3000 Switch Command Reference
OL-13019-01
Chapter 2 IE 3000 Switch Cisco IOS Commands
show errdisable recovery
show errdisable recovery
Use the show errdisable recovery user EXEC command to display the error-disabled recovery timer
information.
show errdisable recovery [ | {begin | exclude | include} expression]
Syntax Description
Command Modes User EXEC
Command History
Usage Guidelines A gbic-invalid error-disable reason refers to an invalid small form-factor pluggable (SFP) module
interface.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output
are not displayed, but the lines that contain Output are displayed.
Examples This is an example of output from the show errdisable recovery command:
Switch> show errdisable recovery
ErrDisable Reason Timer Status
----------------- --------------
udld Disabled
bpduguard Disabled
security-violatio Disabled
channel-misconfig Disabled
vmps Disabled
pagp-flap Disabled
dtp-flap Disabled
link-flap Enabled
psecure-violation Disabled
gbic-invalid Disabled
dhcp-rate-limit Disabled
unicast-flood Disabled
storm-control Disabled
loopback Disabled
Timer interval:300 seconds
| begin (Optional) Display begins with the line that matches the expression.
| exclude (Optional) Display excludes lines that match the expression.
| include (Optional) Display includes lines that match the specified expression.
expression Expression in the output to use as a reference point.
Release Modification
12.2(44)EX This command was introduced.

Table of Contents

Other manuals for Cisco IE-3000-8TC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco IE-3000-8TC and is the answer not in the manual?

Cisco IE-3000-8TC Specifications

General IconGeneral
Switching Capacity16 Gbps
MAC Address Table Size8000
Uplink Ports2 x 10/100/1000Base-T or SFP (Small Form-Factor Pluggable)
Operating Temperature-40°C to 70°C
MountingDIN rail
Ports8 x Ethernet 10/100Base-TX ports
Jumbo Frame SupportYes