2-495
Cisco IE 3000 Switch Command Reference
OL-13019-01
Chapter 2 IE 3000 Switch Cisco IOS Commands
snmp-server enable traps
Note Though visible in the command-line help strings, the cpu [threshold], insertion, removal, and rtr
keywords are not supported. The snmp-server enable informs global configuration command is not
supported. To enable the sending of SNMP inform notifications, use the snmp-server enable traps
global configuration command combined with the snmp-server host host-addr informs global
configuration command.
Defaults The sending of SNMP traps is disabled.
Command Modes Global configuration
Command History
Usage Guidelines Specify the host (NMS) that receives the traps by using the snmp-server host global configuration
command. If no trap types are specified, all trap types are sent.
When supported, use the snmp-server enable traps command to enable sending of traps or informs.
Note Informs are not supported in SNMPv1.
To enable more than one type of trap, you must enter a separate snmp-server enable traps command
for each trap type.
Examples This example shows how to send VTP traps to the NMS:
Switch(config)# snmp-server enable traps vtp
You can verify your setting by entering the show vtp status or the show running-config privileged
EXEC command.
Related Commands
vlancreate (Optional) Enable SNMP VLAN-created traps.
vlandelete (Optional) Enable SNMP VLAN-deleted traps.
vtp (Optional) Enable VLAN Trunking Protocol (VTP) traps.
Release Modification
12.2(44)EX This command was introduced.
Command Description
show running-config Displays the running configuration on the switch. For syntax information,
select Cisco IOS Configuration Fundamentals Command Reference,
Release 12.2 > File Management Commands > Configuration File
Management Commands.
snmp-server host Specifies the host that receives SNMP traps.