CDM-840 Remote Router MN-CDM840
Ethernet-based Remote Product Management Revision 3
6–50
6.3.3.2.6 Configuration | WAN | BUC (Block Up Converter)
This page is operational only when an optional BLOCK UP CONVERTER is installed.
Use this page to configure BUC parameters, and to display the BUC status for L-Band operation.
Figure 6-24. Configuration | WAN | BUC Page
BUC Control
The valid operating range for each item in this section is noted in parentheses.
BUC Power SupplyUse the drop-down list to select the BUC Power Supply as Off or On.
BUC 10 MHz Reference EnableUse the drop-down list to select the BUC 10 MHz
Reference Enable as Off or On.
BUC Low or High Current Limit (0 to 4000) Enter the BUC current alarm for either limit in
100mA increments.
BUC FSK CommunicationUse the drop-down list to select BUC Phase Shift Keying as Off,
Basic Only, or Basic + Advanced.
BUC FSK AddressUse the drop-down lists to select and address from 1 to 15.
BUC Attenuation (use of this feature requires Comtech Advanced FSK) Enter a value, in 0.25
dB steps, from 0 to 30.