7.3.11 Redundancy Commands and Queries
Parameter
Type
Command
(Instruction
Code
& Qualifier)
Number of
Arguments for
Command or
Response to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code &
Qualifier)
Response to Query
(Target to Controller)
Redundancy
State
N/A
1 byte
Query only.
Returns the redundancy state of the unit in the form x, where:
0=Offline
1=Online
EXAMPLE: <0/RED?[cr]
>0000/RED=1[cr][lf]
N/A
RED?
RED=x
(see Description
of Arguments)
Force 1:1
Switch
FSW=
None
Command only.
This command takes no arguments.
Forces the unit to toggle the Unit Fail relay to the “fail” state for approximately
500 ms.
NOTES:
1) If the unit is a 1:1 pair and it is currently the ‘Online’ unit, this forces a
switchover so the unit will then be in ‘Standby’ mode
2) The command is always executed by the unit regardless of whether it is
stand-alone, in a 1:1 pair, or part of a 1:N system.
EXAMPLE: <0/FSW=[cr]
FSW=
FSW*