EasyManua.ls Logo

Comtec CDM-840 - Configuration | Interface | E1 | Time Slots

Default Icon
372 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CDM-840 Remote Router MN-CDM840
Ethernet-based Remote Product Management Revision 3
6–24
6.3.3.1.3.2 Configuration | Interface | E1 | Time Slots
Figure 6-15. Configuration | Interface | E1 | Time Slots Page
Time Slot Configuration
Time Slots may be selected for transmission or reception up to the maximum dictated by the
selected transmit or receive data rate, and may be selected in prioritized order. For example, if
the Time Slot format is set to Mostly 64k TCHs (Time Channels), the maximum number of Time
Slots that can be dropped or inserted is 64 kbps. From left to right:
Column
Description
Slot
This read-only column identifies the assignable Time Slot (0 through 31).
Selection On / Off
Select the Time Slot as On or Off.
Priority
Use the drop-down list to select the Time Slot priority:
Priority 1
Priority 2
Priority 3.
Format
Use the drop-down list to select the Time Slot format:
Mostly 8k TCHs
Mostly 16k TCHs
Mostly 32k TCHs
Mostly 64k TCHs
Click [Submit] to save.