EasyManua.ls Logo

Comtec CDM-840 - Collect the Pre-Reboot Diagnostic Information from the CDM-840

Default Icon
372 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CDM-840 Remote Router MN-CDM840
Appendix C Revision 3
C–4
C.3 Collect the Pre-Reboot Diagnostic Information from the CDM-840
CAUTIONThis procedure applies only to units running Firmware Version 1.6.2.6 or
newer
.
Step
To do this:
Type this at the Serial Interface “->” prompt:
1 Confirm that the Interfaces are operational.
->info
2 Enable diagnostic information display.
->Shift 6 <cr>
->display_diag_info
Note: You may be prompted to press “enter” and press
“y <CR>” a few times.
3 Collect log files.
->LoggerSnapshot
Wait 30 seconds.
4 Enable traffic logger.
->wan_dll_traffic_log_start()
Allow traffic to run for a brief period.
5 Disable traffic logger.
->wan_dll_traffic_log_stop()
6
End the Serial Interface text capture session.
Make sure to verify that you save the file to
your “temp” folder successfully before
rebooting.
->exit
Refer to your terminal emulator program User Guide or
Help feature.
You may now reboot the CDM-840 and proceed to C.4 Collect and Report the Post-Reboot
Diagnostic Information from the CDM-840.