CDM-840 Remote Router MN-CDM840
Serial-based Remote Product Management Revision 3
7–33
7.3.14 Miscellaneous Utility Commands and Queries
Parameter
Type
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 and 57)
Response to Query
(Target to Controller)
Sets or returns Working Mode in the form x, where:
0=Router Mode
1=BPM (Bridge Point to Multipoint) Mode
EXAMPLE: <0/CWM=0[cr] (Sets Working Mode to Router Mode)
(see Description
of Arguments)
NOTE: THIS COMMAND TAKES NO ARGUMENTS.
Resets Dynamic Power Control and the Entry Channel Mode Tx Base Power
value to the factory default.
CAUTION – YOU SHOULD QUERY THE ENTRY CHANNEL MODE TX
BASE POWER SETTING (<0/EBP=?[cr]) BEFORE USING THIS
COMMAND. YOU MAY RESTORE THE ENTRY CHANNEL MODE TX BASE
POWER VALUE WITH THE ‘EBP’ COMMAND.
NOTE: THIS COMMAND TAKES NO ARGUMENTS.
Forces the system to reboot.
CAUTION – TAKE CARE WHEN USING THIS COMMAND. THE SYSTEM
WILL REQUEST NO CONFIRMATION AND WILL NOT WARN YOU
BEFORE SYSTEM REBOOT OCCURS.
EXAMPLE: <0/FRB[cr]
Execute PING to send four 64-byte ICMP echo request packets to the host. A
valid connection triggers an ICMP response. The host IP Address is in the
form xxx.xxx.xxx.xxx.
EXAMPLE: <0/PING[sp]xxx.xxx.xxx.xxx[cr]