CDM-840 Remote Router MN-CDM840
Serial-based Remote Product Management Revision 3
7–33
7.3.14 Miscellaneous Utility Commands and Queries
Parameter
Type
Command
(Instruction
Code
& Qualifier)
Number of
Arguments for
Command or
Response to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code &
Qualifier)
Response to Query
(Target to Controller)
Change
Working
Mode
CWM=
1 byte
Command or Query.
Sets or returns Working Mode in the form x, where:
0=Router Mode
1=BPM (Bridge Point to Multipoint) Mode
EXAMPLE: <0/CWM=0[cr] (Sets Working Mode to Router Mode)
CWM =
CWM?
CWM *
CWM #
CWM ?
CWM=x
(see Description
of Arguments)
Reset DPC
power to
factory
default
DPD=
None
Command only.
NOTE: THIS COMMAND TAKES NO ARGUMENTS.
Resets Dynamic Power Control and the Entry Channel Mode Tx Base Power
value to the factory default.
CAUTION YOU SHOULD QUERY THE ENTRY CHANNEL MODE TX
BASE POWER SETTING (<0/EBP=?[cr]) BEFORE USING THIS
COMMAND. YOU MAY RESTORE THE ENTRY CHANNEL MODE TX BASE
POWER VALUE WITH THE ‘EBP’ COMMAND.
EXAMPLE: <0/DPD[cr]
DPD=
DPD *
N/A
N/A
Force Reboot
FRB=
N/A
Command only.
NOTE: THIS COMMAND TAKES NO ARGUMENTS.
Forces the system to reboot.
CAUTION TAKE CARE WHEN USING THIS COMMAND. THE SYSTEM
WILL REQUEST NO CONFIRMATION AND WILL NOT WARN YOU
BEFORE SYSTEM REBOOT OCCURS.
EXAMPLE: <0/FRB[cr]
FRB=
FRB*
N/A
N/A
Ping Host
PING[sp]
16 bytes
Command only.
Execute PING to send four 64-byte ICMP echo request packets to the host. A
valid connection triggers an ICMP response. The host IP Address is in the
form xxx.xxx.xxx.xxx.
EXAMPLE: <0/PING[sp]xxx.xxx.xxx.xxx[cr]
PING =
N/A
N/A