CDM-840 Remote Router MN-CDM840
Ethernet-based Remote Product Management Revision 3
6–56
Query Interval (1 to 60) Enter a value, in seconds. The default is 1 second. This is the
interval between general queries sent by the unit. By varying the query interval, the
administrator may tune the number of IGMP messages on the subnet; note that larger
numbers cause the IGMP queries to be sent less often.
Query Response Interval (1 to 25) This is the maximum response time inserted into the
periodic general queries. By varying the Query Response Interval, the administrator may
tune the “burstiness” of IGMP messages on the subnet; note that larger values make the
traffic less “bursty” as host responses are spread out over a large interval.
The number of seconds assigned to the Query Response Interval must be less
than the Query Interval.
Click [Submit] to save.
IGMP Table
This read-only table lists the IGMP Groups that are active on the unit. This allows you to
determine which services are being used and the minimum time before a service will be
terminated.
Click [Refresh] to update this section with its latest available statistics.