CDM-570A/570AL Satellite Modem with Optional Packet Processor
Revision 5
Serial-based Remote Product Management 8–60 MN-CDM570A
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction Code
and Qualifier)
Response to
Query
BUC Software
Version
N/A
2 bytes
Query only.
Returns the BUC software version in the form xx.
When unavailable, response is 00
Note: Command valid only when the FSK and BUC power are turned On.
Example: <0/BSV?
>0/BSV=05 (Software version 05)
N/A
BSV?
BSV=xx
(see Description of
Arguments)
BUC Temperature
N/A
3 bytes
Query only.
Returns BUC temperature is returned, in the form sxx, where:
s = sign (+ or –)
xx = value
When unavailable, response is 99
Note: This query is valid only when the FSK and BUC power are turned On.
Example: <0/BUT?
>0/BUT=13 (BUC temperature is 13 degrees C)
N/A
BUT?
BUT=sxx
(see Description of
Arguments)