CDM-570A/570AL Satellite Modem with Optional Packet Processor
Revision 5
Serial-based Remote Product Management 8–60 MN-CDM570A
Parameter
Type
(Instruction
Code and
Qualifier)
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction Code
and Qualifier)
Response to
Query
Version
Returns the BUC software version in the form xx.
When unavailable, response is 00
Note: Command valid only when the FSK and BUC power are turned On.
Example: <0/BSV?
>0/BSV=05 (Software version 05)
(see Description of
Arguments)
Returns BUC temperature is returned, in the form sxx, where:
s = sign (+ or –)
xx = value
When unavailable, response is –99
Note: This query is valid only when the FSK and BUC power are turned On.
Example: <0/BUT?
>0/BUT=–13 (BUC temperature is –13 degrees C)
(see Description of
Arguments)