82Dallmeier electronic
Housekeeping-
System motoring
This message will be send if the system monitoring Sys-
tem monitoring (housekeeping) detects an event of the
category „info“.
Events of the category „info“ are:
- The internal temperature is in the upper/lower/normal
range.
- The external temperature is in the upper/lower/normal
range.
- The CPU temperature is in the upper/lower/normal
range.
- The average system temperature is in the upper/lower/
normal range.
- The internal/external/CPU or average system temperature
has reached the upper limit. The recorder will be shut
down.
- The revolution of the front fan is too high/too low/nor-
mal.
- The revolution of the rear fan is too high/too low/
normal.
- The revolution of the HDD fan is too high/too low/
normal.
Camera failure This message will be send if fails or is working again.
Camera contact This message will be send if the recorder starts recording
of a camera because of a contact IN function (Start recor-
ding camera (recording mode Contact).
No Recording This message will be send if no recording is triggered in a
particular track in a dened period. Relevant are cameras/
tracks with the recording mode motion or contact. The
appropriate conguration is done in Setup > System >
Options > Recording Timeouts.
SEDOR
®
-Alarm Sabotage This message will be send if SEDOR
®
detects a sabotage
event on a camera (defocusing, turning, covering).
SEDOR
®
Error This message will be send if SEDOR
®
detects an internal
error.
Sensor contact This message will be send if the sensor (sensor card SK6)
detects a movement and thus triggers a recording.
The current recorder version does not support this mes-
sage (no SK6).
Overow Exeeded This message will be send if more then 80% of the video
memory is occupied.
Overow Not Exceeded This message will be send if the occupation of the video
memory falls below 80% again (e. g. when tracks have
been deleted).
Standard Track Saved This message will be send if the recorder saves a Secure
Track from being overwritten. It is irrelevant which event
(Alarm or Contact IN) triggers the saving function.

Table of Contents

Other manuals for dallmeier DLS 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the dallmeier DLS 4 and is the answer not in the manual?

dallmeier DLS 4 Specifications

General IconGeneral
Branddallmeier
ModelDLS 4
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals