AH500 Module Manual
8-32
Constant: Data is a constant.
Format: Users can select Hex, ASCII, or Code in the Format box. If Code is selected, data used
is a control code.
Value: User can enter a constant.
Variable: Data is a variable. Users can specify an internal register in AH10/15SCM-5A, or a
register in a CPU module.
Format: Users can set the format of data
Null: Data is not processed.
Hex: ASCII data is converted into hexadecimal data. ASCII data which can not be converted into
hexadecimal data will be converted into 0.
ASCII: Hexadecimal data is converted into ASCII data. Hexadecimal data which can not be
converted into ASCII data will be converted into 0.
Variable property
Function: For a TX packet, users can select Read R () in the Function box. For a RX packet, the
users can select Read R (), Write W (), or * in the Function box.
Mapping register: Users can select an internal register in AH10/15SCM-5A, or a register in a CPU
module. I1, I2, O1, and, O2 are internal registers in AH10/15SCM-5A. For a
CPU module, D Register or Base+Offset can be selected.
Register
Definition
Register
Definition
D
Internal data register in a
CPU module
Base+Offset Used with a control register
I1
Used for the
receiving/sending of data
through COM1
O1
Used for the sending of
data through COM1
I2
Used for the
receiving/sending of data
through COM2
O2
Used for the sending of
data through COM2
Length
Class: Users can select 1 Byte or 2 Bytes in the Class box.
Format: Users can select Hex or ASCII in the Format box.
Value: Users can enter a length.
Checksum
Class: Users can select a class.