Chapter 10 DeviceNet Communication Module AH10DNET
10-57
4. Click “OK” to download the configuration to the scanner module. At the moment, the
configuration of the DeviceNet network is completed.
10.9.5 Data Flow Direction
Configure the DeviceNet network following the above steps and the mapping relation between
AH10DNET-5A and the slave device is shown below:
AH500 series CPU module AH10DNET-5A → Slave device
AHCPU510-EN
AH10DNET-5A
(Master)
AH10DNET-5A
(Slave)
AHCPU530-EN
D1505
D2000
D1506 D2001
D1507 D2002
D1508 D2003
D1509 D2004
AH500 series CPU module AH10DNET-5A ← Slave device
AHCPU510-EN
AH10DNET-5A
(Master)
AH10DNET-5A
(Slave)
AHCPU530-EN
D1005
D2500
D1006 D2501
D1007 D2502
D1008 D2503
D1009 D2504
Note: AHCPU510-EN is to monitor and control D0 in AHCPU530-EN via the DeviceNet bus; move
the value in D2000 to D0 and meanwhile move the value in D0 to D2500 in AHCPU530-EN in
real time.