Chapter 11 DeviceNet Remote I/O Module AHRTU-DNET
11-83
To display the mapping relations of the serial port data in the following configuration, please remove
the slave AHRTU-DNET-5A to Scan List of the master AH10DNET-5A and then the mapping
addresses of the serial port data in AH10SCM-5A will be fixed.
After adding AHRTU-DNET-5A to AH10DNET-5A master, set the Input Start and Output Start to
D1005 and D1505 respectively which are the master allocates to AHRTU-DNET-5A and then
download the configuration data to AH10DNET-5A.