Configure legacy protocols Configure X.25 parameters
Digi TransPort WR Routers User Guide 571
Stopping and starting PADs
To stop and start PAD instances, use the following CLI commands:
▪ stoppads: Stops all PAD instances from accepting and performing any PAD commands.
▪ gopads: Resumes processing of PAD commands.
The stoppads and gopads commands can have the PAD number specified in the syntax to stop and
start individual PAD instances.
For example:
▪ To stop PAD 1 from processing PAD commands:
stoppads 1
▪ To re-enable PAD 1:
gopads 1
pad n llmode 1=enabled
0=disabled
Enable Leased Line Mode
pad n enqcon 1=enabled
0=disabled
Send ENQ on Connect
pad n stxmode 1=enabled
0=disabled
Enable STX / ETX Filtering
pad n delconmsg 0-10 Delay connect message n x 10
milliseconds
pad n data_del 0-2147483647 Delay data transfer after connection by
n x 10 milliseconds
pad n inacttim 0-1000 Terminate the PAD call after x seconds if
there has been no data transmission
pad n nocalltim 0-60000 Disconnect the layer 2 call if there is no
layer 3 call in progress for x seconds
pad n trig_str text Create an event when the following data
is on the PAD
pad n inactevent 0-2147483647 Create an event when there has been no
activity on the PAD for x seconds
Entity Instance Parameter Values Equivalent web parameter