Parameter Specification
Remote control General Overvoltage protected remote on/off input.
Overvoltage protection of the remote pin is also 100 V.
If you connect the remote pin to the car battery
directly, the AutoBox will always be turned on, and the
car battery will then soon be exhausted if the engine is
not running. A switch is therefore highly
recommended.
Input resistance at
remote input
44 kΩ tied to GND
Remote on voltage > 4 V
Remote off voltage < 1 V
Power input connector n 7-pin male connector
n Max. 20 µH differential mode inductance for the
supply cabling
n For the pinout, refer to Power Input Connector
on page 279.
Status LEDs n 1 multi-color LED on the bracket of the power
supply board of the AutoBox.
n 3 multi-color LEDs on the component side of the
power supply board of the AutoBox.
n For a description of the display, refer to AutoBox
Status LEDs (Integrated as of AutoBox Version 4.0)
on page 281.
Shock and
vibration test
EN 600068-2-6 n Mechanical test of resistance to vibration
n Test conditions: Sinusoidal vibration, 3-axis test,
5 … 2000 Hz, up to 9 g, 30 minutes per axis
n During the test AutoBox continuously executed a
program, including I/O without any failures.
EN 600068-2-27 n Mechanical test of shock resistance
n Test conditions: Shock, 3-axis test, 11 ms at 15 g
n During the test AutoBox continuously executed a
program, including I/O without any failures.
Mounting positions n Horizontal position (with shock mounts below)
n Vertical position
n Not allowed: upside down position
Grounding Circuit ground is connected to ground of the
backplane, which is isolated from car battery ground.
Physical size Refer to AutoBox Dimension Drawings on page 277.
s
Accessories
t
274
s
DS1103 Hardware Installation and Configuration November 2014