One mating connector with connecting leads is included in the
Tandem-AutoBox package (up to TandemAutoBox Version 4.0 = two
connectors).
This cable is intended to operate the Tandem-AutoBox with a
laboratory power supply during development. Therefore, pin 4
(remote) is shorted to pin A2 inside the connector in order to save a
separate switch. Do not use this cable in the vehicle. Otherwise, the
Tandem-AutoBox will always be turned on.
As of March 2009, the VBAT wire (red) contains a melting fuse. The
melting fuse must provide the following characteristics: 60 A/32 V,
time lag.
The red wire has a cross-section of 10 mm², the black wire of 6 mm².
To avoid damage, do not use a cable with cross-sections less than 6
mm². Note that the cable which is supplied to connect MicroAutoBox
1401/1507 to the power supply provides only 1.5 mm² cross-section
wires.
Matching cable
WA R NI NG
Hazardous voltages
Even a brief disconnection of the battery while the engine
is running results in a load dump of the car generator
producing hazardous voltages of more than 100 V.
n Turn off the engine while connecting or disconnecting
the car battery.
N O T I C E
Reverse polarity destroys the Tandem‑AutoBox
power supply even if the remote control input is
turned off.
n Double check the supply voltage polarity of AutoBox.
Warnings
s
Accessories
t
294
s