HAPTER
15
| Basic Administration Protocols
Configuring Event Logging
– 354 –
◆ Logging Facility – Sets the facility type for remote logging of syslog
messages. There are eight facility types specified by values of 16 to 23.
The facility type is used by the syslog server to dispatch log messages
to an appropriate service.
The attribute specifies the facility type tag sent in syslog messages (see
RFC 3164). This type has no effect on the kind of messages reported by
the switch. However, it may be used by the syslog server to process
messages, such as sorting or storing messages in the corresponding
database. (Range: 16-23, Default: 23)
◆ Logging Trap Level – Limits log messages that are sent to the remote
syslog server for all levels up to the specified level. For example, if level
3 is specified, all messages from level 0 to level 3 will be sent to the
remote server. (Range: 0-7, Default: 7)
◆ Server IP Address – Specifies the IP address of a remote server
which will be sent syslog messages.
WEB INTERFACE
To configure the logging of error messages to remote servers:
1. Click Administration, Log, Remote.
2. Enable remote logging, specify the facility type to use for the syslog
messages. and enter the IP address of the remote servers.
3. Click Apply.
Figure 203: Configuring Settings for Remote Logging of Error Messages

Table of Contents

Other manuals for Edge-Core ES3510MA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edge-Core ES3510MA and is the answer not in the manual?

Edge-Core ES3510MA Specifications

General IconGeneral
BrandEdge-Core
ModelES3510MA
CategorySwitch
LanguageEnglish

Related product manuals