System manual CECX / Analog output module CECX-A-4A-V
CECX-II 20-8
20.5 Configuration
20.5.1 General information
A CECX-system needs data for the configuration of system performance,
its I/O-devices and interfaces. The system reads this data during the start-
up operation and allocates them to its components and devices.
Configuration data is created by included configuration tools.
20.5.1.1 Setting the address
The modules are addressed via the address switch. A maximum of 12
modules of the same type can be distinguished on one line.
The address switch is located on the right side underneath the lower cover.
The K-Bus plug is located underneath the upper cover.
0
1
F
2
3
4
5
6
7
8
9
A
B
C
D
E
1
Position of the address switch
1 ....Address switch
On leaving the factory all modules are set to address 0 and both covers are
closed.
Note
Modules of the same type that are installed within the same line must have
different address switch positions. Different modules (e.g. CECX-C-2G2
and CECX-A-4A-V) may have the same address switch positions.
The lids for the K-Bus plug and the address switch must remain locked at
the last module in the line (to protect it against dirt and damage through
electrostatic discharge on contact).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Festo CECX-X-C1 Series and is the answer not in the manual?

Festo CECX-X-C1 Series Specifications

General IconGeneral
BrandFesto
ModelCECX-X-C1 Series
CategoryController
LanguageEnglish

Related product manuals