EasyManua.ls Logo

Fujitsu M10-4 - Page 142

Fujitsu M10-4
342 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table
7-10
  
Inactive/cold
replacement
work
procedure
(building
block
configuration
only)
Item
Work
procedure Reference
1 Opening
the
rack
door
2 Switching
the
mode
switch
on
the
operation
panel
to
Service
mode
"5.2
Switching
the
Mode
Switch
to
Service
Mode"
3 Checking
the
operating
condition
of
the
system
and
the
I/O
device
usage
status
"5.3
Checking
the
Operating
Condition
and
Resource
Usage
Status"
4 Powering
off
the
chassis
requiring
maintenance
"
5.5
Powering
Off
the
Physical
Partition
Requiring
Maintenance"
5
Releasing
the
chassis
requiring
maintenance
from
the
system
"5.8.1
Releasing
of
the
SPARC
M10-4S
chassis
(possible
only
in
a
system
with
a
building
block
configuration)"
6 Enabling
access
to
the
FRU
requiring
maintenance
"5.9
Accessing
an
FRU"
7 Replacing
a
faulty
FRU See
the
removal
and
installation
procedures
in
the
maintenance
procedures
for
each
FRU
(Chapters
8
to
17).
"Chapter
8
Maintaining
the
PCI
Express
Cards"
"Chapter
9
Maintaining
the
CPU
Memory
Unit/Memory"
(*1)(*2)
"Chapter
10
Maintaining
the
Internal
Disks"
"Chapter
11
Maintaining
the
Fan
Units"
"Chapter
12
Maintaining
the
Power
Supply
Units"
"Chapter
13
Maintaining
the
PSU
Backplane
Unit/
Operation
Panel"
(*1)
"Chapter
14
Maintaining
the
Crossbar
Cables"
"Chapter
15
Maintaining
the
Crossbar
Units"
"Chapter
16
Maintaining
the
XSCF
BB
Control
Cables"
"Chapter
17
Maintaining
the
XSCF
DUAL
Control
Cables"
8
Restoring
the
chassis
requiring
maintenance
"6.1
Restoring
the
Chassis"
9 Incorporating
the
chassis
requiring
maintenance
into
the
system
"6.2.1
Incorporation
of
the
SPARC
M10-4S
chassis
(possible
only
in
a
system
with
a
building
block
configuration)"
10 Diagnosing
the
chassis
requiring
maintenance
"6.3.1
Diagnosing
the
system
board"
(*3)
"6.3.2
Diagnosing
the
crossbar
unit
and
crossbar
cables"
11 Confirming
that
there
is
no
problem
with
the
replacement
FRU
"4.2.2
Identifying
a
failure"
-
"Checking
the
FRU
status"
12 Returning
the
mode
switch
on
the
operation
panel
to
Locked
mode
"6.6
Returning
the
Mode
Switch
to
Locked
Mode"
13 Powering
on
the
chassis
requiring
maintenance
"6.7
Powering
On
the
Physical
Partition
Requiring
Maintenance"
Fujitsu
M10-4/Fujitsu
M10-4S/SPARC
M10-4/SPARC
M10-4S
Service
Manual
November
2014128

Table of Contents

Related product manuals