Remove all PSUs, see "Removing a hot-plug PSU" on page 106.
"Getting access to the component" on page
47.
"Removing the air duct" on page 58.
"Removing the fan holder" on page 60.
Remove all expansion cards, see "Removing the expansion card" on
page 237.
Before removing the expansion cards, take a note on the installation
slot number for each card. Ensure that you install the card again in
the slot it was located before the replacement.
"Removing the crossbar" on page 62.
Remove all memory modules, see "Removing a memory module" on
page 266.
Before removing the memory modules, take a note on the installation
slot number for each memory module. Ensure that you install the
memory modules again in the slot they were located before the
replacement.
If applicable, remove the iRMC microSD card, see "Removing the iRMC
microSD card" on page 403
.
If applicable, remove all M.2 SSDs, see "Removing the M.2 SSD" on
page 410.
Removing the system board
Disconnect all cables from the system board.
System board and components