70 Upgrade and Maintenance Manual
TX1310 M1
Basic software procedures
This is the case for the following backup software solutions:
Netvault for Windows
–ARCServe
BackupExec
I Procedures may differ depending on the backup software. For details,
refer to the dedicated documentation provided separately.
Further information on suitable backup software solutions and related
documentation is available to Fujitsu service partners from the Fujitsu
Extranet pages.
Re-enabling backup drives
If a backup drive has been disabled or deleted from the backup software drive
list as described in section 5.1.3 on page 65, it has to be re-enabled to complete
the maintenance task.
Ê Re-enable backup drives and revise backup software settings and cronjobs.
I Detailed information on suitable backup software solutions and
related documentation is available to Fujitsu service partners from the
Fujitsu Extranet pages
5.2.4 Enabling replaced components in the system BIOS
When a processor, an expansion card, or a memory module fails, the defective
component will be set to Disabled or Failed in the system BIOS. The server will
then reboot with only the intact hardware components remaining in the system
configuration. After replacing the defective component, it needs to be re-
enabled in the system board BIOS.
Ê Enter the BIOS.
Ê Select the Advanced menu.
Ê Select the status menu of the desired component:
Processors: CPU Status
I This option is only available for multi-processor systems.
Memory: Memory Status
Expansion cards: PCI Status