EasyManua.ls Logo

Fujitsu PRIMERGY TX1310 M1

Fujitsu PRIMERGY TX1310 M1
232 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TX1310 M1
Upgrade and Maintenance Manual 145
Processo
r
11.2.3 Removing processor
V CAUTION!
Processors are extremely sensitive to electrostatic discharge and must
be handled with care. After a processor has been removed from its
protective sleeve or from its socket, place it upside down on a
nonconducting, antistatic surface. Never push a processor over a
surface.
11.2.3.1 Preliminary steps
Ê "Disabling BitLocker functionality" on page 63
Ê "Shutting down the server" on page 40
Ê "Disconnecting the server from the mains" on page 41
Ê "Getting access to the component" on page 42
Ê "Removing the heat sink" on page 143
11.2.3.2 Removing a processor
I This description applies to the following procedures:
Removing processor from a defective system board (see section
"Replacing the system board" on page 206)
Ê Remove the desired processor heat sink as described in section "Removing
the heat sink" on page 143.
Field Replaceable Unit
(FRU)
Hardware: 15 minutes
Software: 5 minutes
Tools: Tool-less

Table of Contents

Other manuals for Fujitsu PRIMERGY TX1310 M1