The engine should be emptied by draining the oil
through the drainage plug «C» placed under the
engine crankcase.
Since a certain quantity of oil still remains in the
circuit, refill with approx. 2600 cm³ of oil through
the cap «A». The engine has a reference «G» in-
dicating that the maximum oil level has been
reached inside the crankcase. This reference must
be used only when changing oil, whereas the cap/
dipstick «B» must be used when checking oil level.
Then start up the vehicle, let it run for a few mi-
nutes and shut it off. After about 5 minutes, check
the level and, if necessary, top-up but never ex-
ceeding the MAX level reference mark «G» sight
glass on the right crankcase. For top-ups and oil
changes, use new oil of the recommended type.
Recommended products
AGIP CITY HI TEC 4T Engine oil
SAE 5W-40, API SL, ACEA A3, JASO MA Syn-
thetic oil
Always check the oil level before carrying out top-ups. For topping-up:
- Unscrew and remove cap «B».
- Top up the oil in the reservoir until you reach the correct level.
Maintenance GP 800 i.e.