Gilera GP 800 i.e. - Valve Clearance and Cooling System

Gilera GP 800 i.e.
431 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Checking the valve clearance
Front head
- Remove the plastic parts in order to free the head
cover access.
- Undo the six fixing screws and remove the tappet
cover together with the gasket.
- Check the valve clearance, and if necessary, re-
store the correct clearance.
Characteristic
Valve clearance
Inlet: 0.15 mm
Outlet: 0.15 mm
See also
Side fairings
Air filter
Rear head
- Remove the plastic parts in order to free the head
cover access.
- Undo the six fixing screws and remove the tappet
cover together with the gasket.
- Check the valve clearance, and if necessary, re-
store the correct clearance.
Characteristic
Valve clearance
Inlet: 0.15 mm
Outlet: 0.15 mm
See also
Helmet bay
- According to the procedure described in the «Engine Chapter» fit the tappet cover.
See also
Refitting the rocker-arms cover
GP 800 i.e. Maintenance
MAIN - 13

Table of Contents