Table 59: IAX Register Trunk Configuration Parameters
Basic Settings
Provider Name
Configure a unique label to identify this trunk when listed in outbound rules,
inbound rules etc.
Host Name
Configure the IP address or URL for the VoIP provider’s server of the trunk.
Keep Trunk CID
If enabled, the trunk CID will not be overridden by extension's CID when the
extension has CID configured.
The default setting is "No".
Disable This Trunk
If selected, the trunk will be disabled.
Caller ID
Configure the Caller ID. This is the number that the trunk will try to use when
making outbound calls. For some providers, it might not be possible to set the
CallerID with this option and this option will be ignored.
Important Note: When making outgoing calls, the following priority order rule will
be used to determine which CallerID will be set before sending out the call :
From user (Register Trunk Only) CID from inbound call (Keep Original CID
Enabled) Trunk Username/CallerID (Keep Trunk CID Enabled) DOD
Extension CallerID Number Trunk Username/CallerID (Keep Trunk CID
Disabled) Global Outbound CID.
CallerID Name
Configure the name of the caller to be displayed when the extension has no
CallerID Name configured.
Username
Enter the username to register to the trunk from the provider.
Password
Enter the password to register to the trunk from the provider.
Advanced Settings
Codec Preference
Select audio and video codec for the VoIP trunk. The available codecs are: PCMU,
PCMA, GSM, AAL2-G.726-32, G.726, G.722, G.729, G.723, iLBC, ADPCM,
H.264, H.265, H.263, H.263p and VP8.
Enable Heartbeat
Detection
If enabled, the UCM630X will regularly send SIP OPTIONS to the device to check
if the device is still online. The default setting is "No".
Heartbeat Frequency
When "Enable Heartbeat Detection" option is set to "Yes", configure the interval
(in seconds) of the SIP OPTIONS message sent to the device to check if the device
is still online. The default setting is 60 seconds.
Maximum Number of
Call Lines
The maximum number of concurrent calls using the trunk. The default settings 0,
which means no limited.
FECC
Configure to enable Remote Camera Management.

Table of Contents

Other manuals for Grandstream Networks UCM63 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grandstream Networks UCM63 Series and is the answer not in the manual?

Grandstream Networks UCM63 Series Specifications

General IconGeneral
BrandGrandstream Networks
ModelUCM63 Series
CategoryPBX
LanguageEnglish

Related product manuals