COMMAND DETAILS
115
Parameter
<X>
Reference waveform 1, 2, 3, 4.
<NRf>
Horizontal co-ordinates
Return parameter
<NR3>
Returns the reference waveform position
Example
:REF1:TIMebase:POSition -5.000E-5
Selects reference 1, and then sets the horizontal
position to -50us.
:REF<X>:TIMebase:SCALe
Description
Sets or returns the selected reference waveform
time base scale.
Syntax
:REF<X>:TIMebase:SCALe { <NRf> | ?}
Related
commands
:REF<X>:DISPlay
Parameter
<X>
Reference waveform 1, 2, 3, 4.
<NRf>
Horizontal scale
Return parameter
<NR3>
Returns the reference waveform scale.
Example
:REF1:TIMebase:SCALe 5.00E-4
Selects reference 1, and then sets the horizontal
scale to 500us/div.
:REF<X>:OFFSet
Description
Sets or returns the selected reference waveform
vertical position (offset).
Syntax
:REF<X>:OFFSet { <NRf> | ?}
Related
commands
:REF<X>:DISPlay
Parameter
<X>
Reference waveform 1, 2, 3, 4.
<NRf>
Vertical offset
Set
Query
Set
Query