EasyManua.ls Logo

GW Instek GDS-1000B Series - Bus1; Bus1:State; Bus1:Type

GW Instek GDS-1000B Series
259 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
COMMAND DETAILS
171
:BUS1:LIN:POLARity .................................................183
:BUS1:LIN:SAMPLEpoint ..........................................183
:BUS1:LIN:SOURce ...................................................183
:BUS1:LIN:STANDard ...............................................184
:BUS1
Description
Returns the supported BUS types.
Syntax
:BUS1?
Return Parameter
Returns the supported bus types.
Example
BUS1?
I2C,SPI,UART, CAN, LIN
:BUS1:STATE
Description
Sets or queries the state of the bus.
Syntax
:BUS1:STATE { OFF | ON | ? }
Related
commands
:BUS1:TYPe
Parameter/Return
parameter
OFF
Turns the bus off.
ON
Turns the bus on.
Example
:BUS1:STATE ON
Turns the bus on.
:BUS1:TYPe
Description
Sets or queries the type of bus.
Syntax
:BUS1:TYPe { UART | I2C | SPI | CAN | LIN | ? }
Related
commands
:BUS1:STATE
Query
Set
Query
Set
Query

Table of Contents

Other manuals for GW Instek GDS-1000B Series