COMMAND DETAILS
161
:TRIGger:BUS:B1:LIN:ERRTYPE
Description
Sets or returns the error type be used for the LIN
trigger.
Note
This command is only applicable when the Serial
Bus Decode (DS1B-BUS) option is installed. See the
user manual for details.
Syntax
:TRIGger:BUS:B1:LIN:ERRTYPE
{SYNC|PARIty|CHecksum|?}
Parameter/
Return parameter
SYNC
Sets the LIN error type to SYNC.
PARIty
Sets the LIN error type to parity.
CHecksum
Sets the LIN error type to checksum.
Example
:TRIGger:BUS:B1:LIN:ERRTYPE?
>SYNC
:TRIGger:BUS:B1:LIN:ERRTYPE CHECKSUM
:TRIGger:BUS:B1:LIN:ERRTYPE?
>CHECKSUM
:TRIGger:BUS:B1:LIN:IDentifier:VALue
Description
Sets or returns the identifier string to be used for
the LIN trigger.
Note: Only applicable when the condition is set to
ID or IDANDDATA.
Note
This command is only applicable when the Serial
Bus Decode (DS1B-BUS) option is installed. See the
user manual for details.
Syntax
:TRIGger:BUS:B1:LIN:IDentifier:VALue {<string>|?}
Set
Query
Set
Query