GDS-1000B Programming Manual
206
Example 1
:SEARCH:TRIGger:BUS:B1:UART:CONDition TXDATA
:SEARCH:TRIGger:BUS:B1:UART:TX:DATa:SIZe 1
:SEARCH:TRIGger:BUS:B1:UART:TX:DATa:VALue
"1x1x0101"
Sets the value to 1x1x0101
Example 2
:SEARCH:TRIGger:BUS:B1:UART:TX:DATa:VALue?
1X1X0101
:SEARCH:TRIGger:BUS:B1:SPI:CONDition
Description
Sets or queries the SPI search triggering condition.
Syntax
:SEARCH:TRIGger:BUS:B1:SPI:CONDition {SS | MISO
| MOSI | MISOMOSI | ? }
Parameter
SS
Set to trigger on the Slave Selection
condition.
MISO
Set to trigger on the Master-In
Slave-Out condition.
MOSI
Set to trigger on the Master-Out
Slave-In condition.
MISOMOSI
Set to trigger on the Master-In
Slave-Out and Master-Out Slave-In
conditions.
Return Parameter
Returns the triggering condition.
Example
:SEARCH:TRIGger:BUS:B1:SPI:CONDition MISO
Sets the SPI bus to trigger on MISO.
:SEARCH:TRIGger:BUS:B1:SPI:DATa:SIZe
Description
Sets or queries the number of words for SPI data
for the search function.
Note
This setting only applies when the SPI search
trigger is set to trigger on MISO, MOSI or
MISO/MOSI
Set
Query
Set
Query