COMMAND DETAILS
179
:BUS1:SPI:MOSI:SOURce
Description
Sets or queries which channel is used for the SPI
MOSI source.
Syntax
:BUS1:SPI:MOSI:SOURce { OFF | CH1 | CH2 | CH3 |
CH4 | ? }
Parameter/Return
parameter
CH1 to CH4
Analog channels CH1 to CH4
OFF
No MOSI source.
Example
:BUS1:SPI:MOSI:SOURce CH1
Sets channel 1 as the SPI MOSI source.
:BUS1:SPI:MISO:SOURce
Description
Sets or queries which channel is used for the SPI
MISO source.
Syntax
:BUS1:SPI:MISO:SOURce { OFF | CH1 | CH2 | CH3 |
CH4 | ? }
Parameter/Return
parameter
CH1 to CH4
Analog channels CH1 to CH4
OFF
No MISO source.
Example
:BUS1:SPI:MISO:SOURce CH1
Sets channel CH1 as the SPI MISO source.
:BUS1:DISplay:FORMAt
Description
Sets or queries the display format for the bus,
either binary or hexadecimal.
Syntax
:BUS1:DISplay:FORMAt { BINary | HEXadecimal |
ASCII | ? }
Parameter/Return
parameter
BINary
Binary format
HEXadecimal
Hexadecimal format
Set
Query
Set
Query