COMMAND DETAILS
119
Timebase Commands
:TIMebase:EXPand ....................................................119
:TIMebase:POSition ..................................................119
:TIMebase:SCALe .......................................................119
:TIMebase:MODe ......................................................120
:TIMebase:WINDow:POSition ..................................120
:TIMebase:WINDow:SCALe ......................................121
:TIMebase:EXPand
Description
Sets or queries the horizontal expansion mode.
Syntax
:TIMebase:EXPand {CENTer|TRIGger|?}
Parameter/Return
parameter
CENTer
Expand from the center of the
display.
TRIGger
Expand from the trigger point.
Example
:TIMebase:EXPand TRIGger
Sets the expansion point to the trigger point.
:TIMebase:POSition
Description
Sets or queries the horizontal position.
Syntax
:TIMebase:POSition {<NRf> | ?}
Parameter
<NRf>
Horizontal position
Return parameter
<NR3>
Returns the horizontal position
Example
:TIMebase:POSition 5.00E-4
Sets the horizontal position as 500us.
:TIMebase:SCALe
Description
Sets or queries the horizontal scale.
Set
Query
Set
Query
Set
Query